Orton 2020 Introduction to Refractories registrtation now open

Dr. Joseph Homeny and the Orton Refractory Testing Staff will be holding The Orton Introduction to Refractories Short Course May 16, 17 & 18, 2020...
Read more...

Covid-19 Announcement

Orton Ceramic Foundation Mandatory Shutdown - The manufacturing and shipping will be shut down due to the State of Ohio mandaory Covid-19 virus
Read more...

2020 Orton International Cone Box Show WInners Announced

2020 Best in Show Award Winner- Karen Kohtz To visit the Cone Box Show Site click here CONGRATULATIONS to all the winners!
Read more...

Tuesday, 22 March 2016
Tools for Conducting a Refractory Failure Analysis
clear

Refractories can be evaluated after their service life to collect critical information that may be used to guide product development and lead to improvement in performance. Evaluation may be conducted after years of service or immediate after a catastrophic failure. Evaluation of a used refractory material may include chemical analysis, measurement of physical properties, measurement of mechanical properties, and/or examination of the refractory microstructure. The American Society for Testing and Materials (ASTM) provides many standard procedures for measuring these properties.

Chemical analysis of refractory materials is typically accomplished through a combination of X-Ray Fluorescence (XRF) and Inductively Coupled Plasma (ICP). A common approach is to analyze the chemistry of the hot face or affected area and the cold face or unaltered area. A representative sample is cut from the refractory and ground into a powder specimen. The specimen is prepared further in the laboratory for analysis. With knowledge of the chemistry, it may be possible to determine what might be affecting the refractory while it is in service.

Physical properties that are commonly measured include percent porosity, bulk density, reversible linear expansion behavior, permanent linear expansion, pyrometric cone equivalent (PCE), permeability, and abrasion resistance. Again, specimens from the hot face or affected area and the cold face or unaltered area are typically measured and compared. If a cold face or unaltered area is not available, it is preferred to measure unused material. In the event that unused material is not available, measured data can be compared to the manufacturer's data sheet. From the measurement of physical properties, it may be possible to determine if the service conditions are affecting the refractory, if the refractory was manufactured properly, or if the refractory was installed properly.

Mechanical Properties that are commonly measured include flexural strength, compressive strength, and creep behavior. Flexural and compressive strength may be evaluated at ambient or elevated temperatures. The creep behavior may be measured using different test temperatures, stresses, and loading types (compressive or flexural). From the measurement of mechanical properties, it may be possible to determine if the service conditions are affecting the refractory, if the refractory was manufactured properly, or if the refractory was installed properly.  

In some cases, particularly if corrosion is suspected, it may be beneficial to closely examine the refractory microstructure. Optical and/or scanning electron microscopes (SEM) are typically utilized. Specimens from the hot face or affected area and the cold face or unaltered area are typically examined. Electron microscopes equipped with energy dispersive spectrometer (EDS) can collect chemistry data and this information can be overlaid on the image to produce chemistry maps. 

Refractory post-mortem analyses provide valuable, technical information. This information can lead to enhanced refractory properties through research and development, process changes, or design changes. Furthermore, this information can lead to reduced downtime, longer refractory, life, and more efficient processes.

Questions?

If you have questions about this event or any of our other products Call Us: 614-895-2663 or Contact Us by Clicking Here

clear
Posted on 03/22/2016 12:21 PM by Jim Litzinger
clear
sun mon tue wed thu fri sat
   1 2 3 4 5
6 7 8 9 10 11 12
13 14 15 16 17 18 19
20 21 22 23 24 25 26
27 28 29 30 31   

Recent Posts

23-Mar-2020
COVID-19 ANNOUNCEMENT
clear

Archives

2020
Feb Mar

2019
Jan Apr Jun Jul

2018
Jan Feb Apr Jul

2017
May Jun Jul

2016
Feb Mar Apr May

2015
Jun Aug

clear

Subscribe