ASTM C67

Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile

A minimum of five full size brick or tile units per type/brand is suggested by ASTM for determination of modulus of rupture, compressive strength, absorption, and saturation coefficient.

Modulus of Rupture: $200/per test of 5
Compressive Strength (includes capping): $460/per test of 5
Absorption: 5 or 24 hour submersion test: $135/per test of 5
Absorption: 1, 2, or 5 hour boil test: $220/per test of 5
Saturation Coefficient: $355/per test of 5

 DOWNLOAD REQUEST FORM »

ABSTRACT

These test methods cover procedures for the sampling and testing of brick and structural clay tile. The tests include modulus of rupture, compressive strength, absorption, saturation coefficient, effect of freezing and thawing, efflorescence, initial rate or absorption, and determination of weight, size, warpage, length change, and void areas. For purposes of these tests, full-size bricks, tiles, or solid masonry units shall be used as test specimens. They shall be representative of the lot of units from which they are to be selected in respect of the range of colors, textures, and sizes and shall be free of or brushed to remove dirt, mud, mortar, or other foreign materials unassociated with the manufacturing process.

This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. SCOPE

1.1 These test methods cover procedures for the sampling and testing of brick and structural clay tile. Although not necessarily applicable to all types of units, tests include modulus of rupture, compressive strength, absorption, saturation coefficient, effect of freezing and thawing, efflorescence, initial rate of absorption and determination of weight, size, warpage, length change, and void area. (Additional methods of test pertinent to ceramic glazed facing tile are included in Specification C126.)

1.2 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

NOTE 1 - The testing laboratory performing this test method should be evaluated in accordance with Practice C1093.

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

COPYRIGHT NOTICE

Extracted, with permission, from ASTM C67 Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile, copyright ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428. A copy of the standard may be purchased from ASTM International, phone 610-832-9555, e-mail: service@astm.org, website: www.astm.org.

 PURCHASE FULL STANDARD »

View Products by Category:

 

Search
clear

FROM THE BLOG...

Orton Welcomes New General Manager!

The Board of Trustees of the Edward Orton Jr. Ceramic Foundation announces the retirement of its General...

How Kiln Environment will affect a Pyrometric Cone

Those experienced in firing ceramics know that kiln atmosphere can have a major influence on the reaction...

TempTabs: What They Are & How They Work - Watch This Video!

TempTabs are used to measure temperature uniformity, consistency and repeatability in high temperature...